Fischer through bolts data sheet

WebThe fischer injection mortar FIS EM Plus is a high-quality epoxy mortar for top load-bearing capacity in cracked and non-cracked concrete and for seismic applications in performance categories C1 and C2. It is suitable for fixations of shear connectors for concrete layers, tall shelvings, and heavy steel constructions both inside and outside. Webdin 6914 hexagon bolt p1 & p2 (8.8/10.9) square head holding down bolt bs 7419; din 975 threaded rods; countersunk, socket and cup head allen bolt; metric hex head bolt detail; …

Fischer FAZ II Through Bolt M10 x 95mm Through Bolts Fastco

WebFischer 12 x 150mm 501419 FAZ II Through Bolt A4 Stainless Steel Pack of 20. The Fischer FAZ II Through Bolt is a high specification steel anchor for the most demanding requirements. Heavy loads can be secured in cracked concrete using the FAZ II steel anchor. The tried-and-tested expansion clip safely introduces the loads into the concrete … WebFast, cost saving installation from one side. For square, rectangular and circular hollow sections. High resistance to tensile and shear loads. High Clamping Force design (size 5 ⁄ 8 " & 3 ⁄ 4 "). Low temperature tested to -50°F (carbon steel variants). Other head types available. Independently tested for dynamic load applications. how many stanley cups does gretzky have https://davesadultplayhouse.com

Bolt anchor - fischer fixings

WebThe cone bolt expands against the wall of the drill hole. The anchors are made from normal steel, hot-dip galvanised steel, A4 stainless steel, and highly corrosion-resistant steel. … WebLoads Wedge Anchor FWA Recommended loads of a single anchor1) in normal concrete of strength class C20/25. Non-cracked concrete Material / surface3) Effective anchorage … WebThe resin capsule RSB is a system component of the fischer Superbond-System FSB for the introduction of high loads in cracked and non-cracked concrete. European Technical Approval Option 1 for cracked concrete including seismic loads in performance category C1 and classification into fire resistance class R120 offer added safety. how many stanley cups did dominik hasek win

SECTION 1: Identification of the substance/mixture and of the …

Category:Products - fischer fixings

Tags:Fischer through bolts data sheet

Fischer through bolts data sheet

Heavy Duty Fixings Anchor Bolts - Orbital Fasteners

WebFischer FXA Throughbolts M12 x 146mm 20 Pack (49007) Fischer FXA Throughbolts M12 x 146mm 20 Pack. Zinc-plated steel. Suitable for non-cracked concrete. Ideal for steel … WebOrbital Fasteners stock a wide range of heavy duty anchor fittings which include through bolts, anchor bolts and apt anchors. Buy Rawlbolts & shield anchors from Orbital Fasteners. ... Sheet Metal Fasteners & Riveting Tools ... Fischer FNA II 6 x 30/5 Hammerset Nail Anchor 44115.

Fischer through bolts data sheet

Did you know?

WebThese heavy duty anchor bolts that can be used for various type of fixing applications such as bolt down posts and bollards. Please check the suitability for your application before purchase. This item includes both the bolt, shield anchor and washer. Graded 8.8 steel Finished in durable Zinc Plating for corrosion resistance. WebThe cone bolt expands against the wall of the drill hole. The anchors are made from normal steel, hot-dip galvanised steel, A4 stainless steel, and highly corrosion-resistant steel. They safely introduce the loads into the base material through friction locking.

WebJan 21, 2024 · Fischer FXA Throughbolt 16 x 145mm By Fischer Product code: 72385 Pack size: 10 Pack £18.99 Exc. VAT £15.82 ★★★★★ ★★★★★ Selected Quantity Select from 16 variations Collection Delivery Login to save for later Product Details A fixing for flexible use in non-cracked concrete and is suitable for pre-positioned and push-through … WebEfficient fixing for cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel highly corrosion-resistant steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60, cracked and non-cracked …

WebThe FAZ II is suitable for pre-positioned and push-through installation and is also ideal for stand-off installation thanks to the long thread. ... General construction technique permit - … WebCreated Date: 20131121120135Z

WebAll data in this section applies to: - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - Minimum base material thickness - Concrete C 20/25, f ck,cube = 25 N/mm² b) Data covered by Hilti Technical Data. Design resistance Anchor size M6 M8 M10 Eff. Anchorage depth h ef

WebSteel anchors are a mechanical anchoring solution for heavy loads in concrete. Anchorings in cracked and non-cracked concrete, indoors and outdoors, in highly corrosive … how did the british empire control indiaWebRS Components how did the british government respondWebJun 18, 2024 · Rated 5 out of 5 by hotrod106 from Through Bolts Good product that does the job as they should. Would buy again. Date published: 2024-05-26 ... Do you have a data sheet for the fixings or a pull test? Asked by: jameslingard ... Bolt Size: M12: Brand: Fischer: CE Standard (Tested to EN...) ETA-13/0772. Drill Size: 12 mm: how did the british empire collapseWeb(xurshdq7hfkqlfdo$vvhvvphqw (7$ (qjolvkwudqvodwlrqsuhsduhge\',%w 3djh ri _ -xo\ = 6shflilf3duw 7hfkqlfdoghvfulswlrqriwkhsurgxfw how did the british empire take over indiaWeb1.3 Details of the supplier of the safety data sheet Company designation fischerwerke GmbH & Co. KG Klaus-Fischer-Straße 1 D-72178 Waldachtal Telephone: +49(0)7443 12-0 FAX: +49(0)7443 12-4222 Email: [email protected] Internet: www.fischer.de Marketer Great Britain: Mrs Mirka Valovicova, fischer Fixing (UK) Ltd Hithercroft Road how many stanley cups did the devils winWebThe cone bolt expands against the wall of the drill hole. The anchors are made from normal steel, hot-dip galvanised steel, stainless steel, and highly corrosion-resistant steel. They … how did the british influence the tanzimatWebRAWLBOLT®Shield Anchor Loose Bolt Performance Data SIZE CONCRETE, fck,cube= 30N/mm2(C20/25) Brickwork = 20.5 N/mm2 CHARACTERISTIC RESISTANCE (kN) DESIGN RESISTANCE (Factored) (kN) RECOMMENDED LOAD (Unfactored) (kN) CHARACTERISTIC EDGE DISTANCE (mm) CHARACTERISTIC SPACING … how did the british preserve eggs during wwll